Location Indicator
VGHS

Aerodrome information
HAZRAT SHAHJALAL INTERNATIONAL AIRPORT, DHAKA [continued]


11. VGHS: Runway Physical Characteristics
Designator RWY NR True & MAG BRG Dimensions of RWY (m) Strength (PCN) and surface of RWY & SWY THR coordinates THR ELEV and highest ELEV of TDZ of PAR Slope of RWY-SWY
14 144 deg True 3200x46 59/F/B/W/T
Asphalt concrete
235118.11N
902318.62E
27 nil
32 324 deg True 3200x46 59/F/B/W/T
Asphalt concrete
234954.00N
902425.40E
27 nil
Designator RWY NR SWY dimensions (m) CWY dimensions (m) Strip dimensions (m) OFZ Remarks
14 275x46 275x153 3750x153 Within the CWY. 25 ft (8m) brick soling with bitumen carpeting shoulder at both side of RWY.
32 275x46 275x153 3750x153

12. VGHS: Declared Distances

RWY

TORA (m)

TODA (m)

ASDA (m)

LDA (m)

Remarks

14

3200

3475

3475

3200

nil

32

3200

3475

3475

3200

nil

RWY:Runway; TORA:Take-off run available; TODA:Take-off distance available;
ASDA:Accelerate-stop distance available; LDA: Landing distance available

13. VGHS: Approach and runway lighting

RWY desi-gnator

APCH LGT type
LEN INTST

THR LGT color WBAR

VASIS (MEHT) PAPI

TDZ LGT LEN

RWY centre line LGT

RWY edge LGT LEN, spacing, color INTST

RWY end LGT color WBAR

SWY LGT

Rem

14

Precision approach CAT-I lighting system

Simple approach lighting system and sequenced flashing lights

Supplementary approach

Green supple-mented by green Wingbar

PAPI 3 deg
MEHT
on slope
67 ft

avbl

avbl

60 m apart white omni-directional with intensity 3%, 10%, 30%, 80%, 100%

Red unidire-ctional Green omnidir-ectional

avbl

nil

32

Simple approach lighting system

Green supple-mented by green Wingbar

PAPI 3 deg
MEHT
on slope
67 ft

avbl

avbl

60 m apart white omni-directional with intensity 3%, 10%, 30%, 80%, 100%

Red unidire-ctional Green omnidir-ectional

avbl

nil

14. VGHS: Other Lighting, Secondary Power Supply

1.

ABN/IBN location, characteristics and hours of operation

ABN: 235057.20N 0902413.24E Over Control TWR)
Altn FLG W G EV 5 Sec (Hours: HN and VIS<3NM) W500 G75

2.

LDI location and LGT
Anemometer location and LGT

Nil
Cup anemometer over Control TWR, windsocks end of RWY 14/32 and int he middle of RWY

3.

TWY edge and centre line lighting

Edge: Blue edge lgts for all TWYs
Centre Line: Nil

4.

Secondary Power Supply/ Switchover time

During main power supply failure, Automatic standby generator power supply available for Apch, RWY, TWY and Apron lighting within 15 seconds

5.

Remarks

APRON LIGTHS: High Intensity Flood Lights


< Previous Page | Next Page >